Model:EV+ ARC
Use:Designed for EV cells and small modules and to fulfil requirements of US ABC & Freedom Car, SAND-2005-3123; SAE J2464 and other National and International prescribed tests
Standard:GB 38031-2020《电动汽车用动力蓄电池安全要求》、GB/T 36276-2023《电力储能用锂离子电池》、 GB 44240-2024《电能存储系统用锂蓄电池和电池组安全要求》、 GB/T 44265—2024《电力储能电站 钠离子电池技术规范》、 UL 9540A《储能系统热失控火蔓延测试评估方法》、 IEC 62619《含碱性或其他非酸性电解质的蓄电池或蓄电池组的安全要求》、 UL 1974:2022
Introduction
The EV+ is an cylindrical calorimeter 40cm in diameter and 44cm depth. Unlike other THT adiabatic calorimeters the lid seals to the base unit. This seal is restricted to below 1 bar and is maintained by electromagnets. This allows for inertion of the environment and the ability to collect products of battery disintegration.
Specification
Chamber dimensions: 40cm diameter x 44cm depth
Temperature range:Ambient* to 300°C
Thermocouple specification: N; Resolution 0.001°C
No. of heaters: 8
Pressure measurement range: 0-30 bar
Sensitivity: 0.02°C/min
Control modes: Adiabatic, Ramping, Isoperibolic, Step Isothermal
Dimensions
Electronics Unit 55cm x 60cm x 107cm;
Blast Box 167cm x 105cm x 116cm
Features
Integrated cables for current and voltage measurement
Video camera
Gas collection line
Ability for battery pressure and temperature measurement
Ability for purging, evaluation, inerting
Options
· OSU
· CPU - Automatic specific heat capacity measurement
· ICU - Integrated single channel battery cycler
· SSS - Single sample gas collection during or after test into collection vessel
· SSU - Gas collection, multi samples
· MPO - Multipoint thermocouple for spatial distribution measurement
· IRU - IR camera for in-situ thermal imaging
· P-NPCO - Pneumatic nail penetration and crush
· CS-NPCO - Controlled speed nail penetration crush option
· RDCS - Rapid data collection system
· LNFO - Liquid nitrogen flow for low temperature application