2022-03-24Download
Model:BTM/BTMC
Use:These gauges are used for measurement of tensile strain of bolt.
These gauges are used for measurement of tensile strain of bolt. They are simply inserted into pre-drilled hole in the bolt with exclusive adhesives. This method is recommendable when an ordinary strain gauges can not be mounted on the bolt surface. Accurate tensile force measurement is possible by calibrating the bolt after installing the bolt gauges.
Applicable specimen | Bolt M10 or larger
| Backing
| Special plastics |
---|---|---|---|
Operational temperature(°C) | -10 ~ +80°C
| Element
| Cu-Ni
|
Temperature compensation range(°C) | —
| Strain limit
| 0.5% (5000×10-6 strain) |
Applicable adhesive
| A-2(BTM) CN(BTMC) | Fatigue life at room temperature | —
|
series BTM
Single-element (G.F. 2.1 approx.)
Type
| Gauge length (mm) | Gauge width (mm) | Backing length (mm) | Backing width (mm) | Resistance (Ω) | Applicable hole diameter (mm) |
BTM-1C | 1 | 0.7 | 5.6 | 1.4 | 120 | ø1.6 |
BTM-6C | 6 | 1.0 | 12.0 | 1.7 | 120 | ø2.0 |
BTM-6CTA | 6 | 1.0 | 12.0 | 1.7 | 120 | ø2.0 |
Each package contains 10 gauges.
Single-element
(G.F. 2.1 approx.)
Type
| Gauge length (mm) | Gauge center a (mm) | Backing diameter b (mm) | Resistance (Ω) | Applicable hole diameter (mm) |
BTMC-05-D10-003LE | 0.5 | 5 | ø0.9 | 120 | ø1.0 |
BTMC-1-D16-003LE | 1 | 5 | ø1.5 | 120 | ø1.6 |
BTMC-3-D20-003LE | 3 | 10 | ø1.9 | 120 | ø2.0 |
Each package contains 10 gauges.series BTMC